ResusciTrack: Cardiac Arrest QI
Cardiac arrest quality improvement, automated. Upload a defibrillator PDF and get a complete case review with clinical benchmarks, an interactive resuscitation timeline, AI-generated coaching, and a ready-to-distribute report in minutes, not hours.
Used by fire departments, EMS agencies, and hospital resuscitation programs running formal cardiac arrest QI.
The Manual Process
- Manually review defibrillator printouts page by page
- Calculate CPR metrics by hand with a stopwatch and calculator
- Write coaching narratives from scratch for every cardiac arrest
- Chase down medical directors for feedback via email threads
- Hours spent per case, most agencies skip QI entirely
The ResusciTrack Way
- Upload a CODE-STAT PDF, metrics are extracted automatically
- 20+ clinical benchmarks calculated instantly against national standards
- AI generates a personalized coaching narrative in seconds
- Medical directors review and approve via a secure link
- Complete case review in minutes, every cardiac arrest gets a QI review
How It Works
From PDF upload to distributed report in six steps. No manual data entry. No spreadsheets.
Upload CODE-STAT Event Log and optional Continuous Complete PDFs from Stryker LIFEPAK defibrillators
System extracts CPR metrics, medications, shocks, compression rates, pulse checks, and device events
20+ benchmarks calculated automatically: CCF, time-to-epi, LUCAS times, compression rates, pause analysis
Claude AI analyzes the metrics and generates a personalized coaching narrative for the crew
Medical director reviews and approves via a secure link. Add feedback through a structured workflow
PDF reports emailed to configurable lists: command staff, medical director, and crew members
Clinical Benchmarks Tracked
Every cardiac arrest is measured against evidence-based resuscitation standards.
Percentage of time compressions are being delivered during the resuscitation
From device power-on to first epinephrine administration
Per-minute rate tracked for each CPR cycle with fatigue detection
Time without compressions during rhythm and pulse checks
Compression pauses before and after defibrillation shocks
Agency-wide ROSC rate trending over time with crew-level comparisons
Track the metrics that matter
Monitor chest compression fraction against the AHA 90% goal line over time. Spot trends, measure improvement, and hold your agency to the standard that saves lives. Every data point comes straight from your Stryker LIFEPAK defibrillator with zero manual entry.
Accountability down to the provider
See exactly how each paramedic performs across every cardiac arrest. Per-provider QA breakdowns show case counts, average CCF, ROSC rates, time to first epinephrine, and more. No other resuscitation tool gives your leadership this level of crew-level insight.
Resuscitation Timeline automatically built with information from CODE-STAT and MetroPCR integration.
Re-live every cardiac arrest, compression by compression.
Case Replay plays back your resuscitation minute-by-minute, synchronizing the LIFEPAK waveform with the PCR, the dispatch timeline, and every compression, shock, and medication. Because static reports don't teach — seeing it happen does.
1-minute walkthrough of a real cardiac arrest scrubbed through Case Replay.
Beat-by-beat rhythm playback with paddles ECG and impedance stacked like the LIFEPAK display. Event popups fire the moment each medication, airway, shock, or LUCAS application happens. CCF and compression rate live on screen — gaps are no longer abstract, they're red squares on the timeline.
MetroPCR charting, the LIFEPAK event log, and the Continuous Complete waveform merged with explicit precedence — no more chasing three tabs to reconstruct what happened. Dispatch time, unit call sign, incident location, and the full provider roster surface the moment you open the replay.
Send a case for medical director review in one click. They sign off inside the browser, and a timestamped audit trail lands back in your QI folder. AI-assisted draft narrative cites the exact moments it references — your medical director edits instead of writes, with the AHA ACLS protocol overlaid moment for moment.
Trend compression fraction, time to first epinephrine, LUCAS apply time, and shock count across every case your department runs. Fatigue detection, longest-pause flags, and rhythm-transition markers expose drift most QI reviews miss. Export any 3-minute window as a training clip for the next crew meeting or onboarding module.
No new hardware, no monitor swap. Case Replay ingests the LIFEPAK Continuous Complete PDF and your MetroPCR chart — the files your crew already generates. Runs in the browser. HIPAA-conscious by design: no patient names, addresses, or dates of birth ingested, and every case stays inside your agency's private environment.
Parses CODE-STAT Event Log PDFs and optional Continuous Complete PDFs from Stryker LIFEPAK 15, LIFEPAK 20, and other LIFEPAK defibrillators. No manual data entry required.
Optionally pull patient care report data (crew info, medications, procedures, narratives, and arrest details) directly from MetroPCR's API to enrich the case review.
ResusciTrack Pricing
Cardiac arrest case review and quality improvement for fire departments and EMS agencies.
- Unlimited app users
- Automated CODE-STAT PDF parsing
- 20+ clinical benchmark calculations
- AI-powered coaching narratives
- Medical director review workflow
- Branded PDF case reports
- Agency dashboard with trend analytics
- Configurable benchmark thresholds
- Email distribution to recipient lists
- Dedicated support
ResusciTrack Add-Ons
One-time custom engineering fees, quoted separately from the base setup.
Auto-pull crew, medications, vitals, procedures, and narrative from MetroPCR into matching ResusciTrack cases
Custom integration with your ePCR system. Most builds take 2-4 weeks and require API access from your vendor.
Bundle this module with others for a discount. See all bundle options.
Clinical standards
ResusciTrack measures every case against the standards medical directors review against.
AHA ACLS 2020 and 2025
Chest compression fraction, compression rate, time to first epinephrine, and pre/post-shock pause thresholds default to AHA-recommended targets and update automatically when the guidelines update.
PALS 2020
Pediatric resuscitation cases use age-stratified compression rate and ventilation targets, with separate benchmarking from adult cases on the same dashboard.
Per-agency benchmark configurability
Override any benchmark to match your medical director's protocol. ResusciTrack flags deviations against your configured targets, not just the national defaults.
Pairs well with
Modules that ship most often alongside ResusciTrack.